THOMAS-CONRAD CORPORATION
TC6843 ARC-CARD/SE
Card Type |
Network Interface Card |
Chip Set |
NCR 90C26 |
NIC Type |
ARCnet |
Network Transfer Rate |
2.5Mbps |
Topology |
Linear Bus, Star |
Wiring Type |
RG-62A/U 93ohm coaxial |
Data Bus |
16-bit Mac SE |
CONNECTIONS | |||
Function |
Label |
Function |
Label |
Header to transceiver |
J1A |
RG-62A/U 93ohm coaxial connector |
J2 |
Header to controller |
J1B |
EXTENDED RANGE CONFIGURATION | ||||
Response Time |
Recon Time |
JP1 |
JP2 | |
» |
74.7 uS |
840 mS |
Open |
Open |
283.4 uS |
1680 mS |
Closed |
Open | |
561.8 uS |
1680 mS |
Open |
Closed | |
11118.6 uS |
1680 mS |
Closed |
Closed | |
Note: This setting should only be changed when the length of the ARCnet segments exceed 6000 meters. |
NODE ADDRESS SELECTION | ||||||||
Setting |
SW1/1 |
SW1/2 |
SW1/3 |
SW1/4 |
SW1/5 |
SW1/6 |
SW1/7 |
SW1/8 |
1 |
Off |
On |
On |
On |
On |
On |
On |
On |
2 |
On |
Off |
On |
On |
On |
On |
On |
On |
3 |
Off |
Off |
On |
On |
On |
On |
On |
On |
4 |
On |
On |
Off |
On |
On |
On |
On |
On |
5 |
Off |
On |
Off |
On |
On |
On |
On |
On |
249 |
Off |
On |
On |
Off |
Off |
Off |
Off |
Off |
250 |
On |
Off |
On |
Off |
Off |
Off |
Off |
Off |
251 |
Off |
Off |
On |
Off |
Off |
Off |
Off |
Off |
252 |
On |
On |
Off |
Off |
Off |
Off |
Off |
Off |
253 |
Off |
On |
Off |
Off |
Off |
Off |
Off |
Off |
Note: A total of 253 node address settings are available. The switches are a binary representation of the decimal memory addresses. SW1/8 is the Most Significant Bit and switch SW1/1 is the Least Significant Bit. The switches have the following decimal values: SW1/8=128, SW1/7=64, SW1/6=32, SW1/5=16, SW1/4=8, SW1/3=4, SW1/2=2, SW1/1=1. Turn off the switches and add the values of the switches to obtain the correct node address. (Off=1, On=0) Addresses 0, 254 and 255 are reserved and should not be used. |