COMPEX, INC.
ANET16-1, ANET16-12
NIC Type |
ARCnet |
Transfer Rate |
2.5Mbps |
Data Bus |
16-bit ISA |
Topology |
Star (ANET16-1) Linear Bus (ANET16-12) |
Wiring Type |
RG-62A/U 93ohm coaxial |
Boot ROM |
Available |
NODE ADDRESS |
||||||||
Node |
SW1/1 |
SW1/2 |
SW1/3 |
SW1/4 |
SW1/5 |
SW1/6 |
SW1/7 |
SW1/8 |
0 |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
Off |
On |
On |
On |
On |
On |
On |
On |
2 |
On |
Off |
On |
On |
On |
On |
On |
On |
3 |
Off |
Off |
On |
On |
On |
On |
On |
On |
4 |
On |
On |
Off |
On |
On |
On |
On |
On |
251 |
Off |
Off |
On |
Off |
Off |
Off |
Off |
Off |
252 |
On |
On |
Off |
Off |
Off |
Off |
Off |
Off |
253 |
Off |
On |
Off |
Off |
Off |
Off |
Off |
Off |
254 |
On |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
255 |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
Note:Node address 0 is used for messaging between nodes and must not be used. A total of 255 node address settings are available. The switches are a binary representation of the decimal node addresses. Switch 1 is the Least Significant Bit and switch 8 is the Most Significant Bit. The switches have the following decimal values: switch 1=1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. Turn off the switches and add the values of the off switches to obtain the correct node address. (On=0, off=1) |
DIAGNOSTIC LED(S) |
||||||
LED |
Color |
Status |
Condition |
|||
LED1 |
Red |
On |
Data is being transmitted |
|||
LED1 |
Red |
Off |
Data is not being transmitted |
|||
LED2 |
Green |
On |
Data is being received |
|||
LED2 |
Green |
Off |
Data is not being received |
TIMEOUT CONFIGURATION |
||||||
Response Time |
JP1 |
JP2 |
||||
» |
74.7µs |
Open |
Open |
|||
|
283.4µs |
Open |
Closed |
|||
|
561.8µs |
Closed |
Open |
|||
|
1118.6µs |
Closed |
Closed |
|||
Note:Timeout is the time required for the network signal to make a complete trip around the network. Using a |
MODE SELECTION |
||
Mode |
JP3 |
|
» |
Normal |
As shown in diagram on previous page |
|
Special |
As shown on diagram on previous page |
Note:In normal mode, any 32KB memory segment in the system may be selected. For an AT, however, with |
I/O BASE ADDRESS |
|||||||
Address |
JP4 |
JP5 |
JP6 |
JP7 |
JP8 |
JP9 |
|
|
260h |
Closed |
Open |
Open |
Closed |
Closed |
Open |
|
280h |
Closed |
Closed |
Closed |
Open |
Closed |
Open |
» |
2E0h |
Closed |
Open |
Open |
Open |
Closed |
Open |
|
2F0h |
Open |
Open |
Open |
Open |
Closed |
Open |
|
300h |
Closed |
Closed |
Closed |
Closed |
Open |
Open |
|
360h |
Closed |
Open |
Open |
Closed |
Open |
Open |
INTERRUPT REQUEST |
||||||||||
IRQ |
JP10 |
JP11 |
JP12 |
JP13 |
JP14 |
JP17 |
JP18 |
JP19 |
JP20 |
|
» |
2/9 |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
|
3 |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
|
4 |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
|
5 |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
|
7 |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
|
10 |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
|
11 |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
|
12 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
|
15 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Note:Jumpers JP17 to JP20 count from right to left in the diagram. |
BOOT ROM ADDRESS |
|||
Address |
JP15 |
JP16 |
|
|
C0000h |
Closed |
Closed |
|
C8000h |
Open |
Closed |
|
CC000h |
Open |
Open |
» |
D0000h |
Closed |
Open |