M 2 6 2 4 T FUJITSU NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 3.5"/HH Cylinders 1429| 995| | Capacity form/unform 513/ MB Heads 11| 16| | Seek time / track 12.0/ 3.0 ms Sector/track 63| 63| | Controller IDE / AT Precompensation Cache/Buffer 64 KB LOOK-AHEAD Landing Zone Data transfer rate 3.050 MB/S int Bytes/Sector 512 7.400 MB/S ext Recording method RLL 1/7 operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 5 45 | -40 60 Power: sleep W Humidity % 20 80 | 5 95 standby W Altitude km 3.000| 12.000 idle 9.5 W Shock g 5 | 50 seek 11.0 W Rotation RPM 4400 read/write 10.0 W Acoustic dBA 43 spin-up W ECC Bit 32,56 MTBF h 20000 Warranty Month Lift/Lock/Park YES Certificates ********************************************************************** L A Y O U T ********************************************************************** FUJITSU M2622T/2623T/2624T OEM MANUAL 41FH5066E-01 +---------------------------------------------------------+ | |XX | |XX | SW1 |XX | LED/CN5 1+---+ |XX I/F | 1--2 |x | |XX | | | |x | |XX | +--+ OFF |x | ON |XX | |x | |XX | |x | |XX | |x | |XX | 6+---+ |XX | |XX | 2+- CNH1 -+8 |XX | 1+--------+7 | | | | |XX Power | |XX +---------------------------------------------------------+ ********************************************************************** J U M P E R S ********************************************************************** FUJITSU M2622T/M2623T/M2624T OEM MANUAL 41FH5066E-01 Switches locations ================== x = Jumpers are set from factory SW1 I/O channel ready signal output ------------------------------------ 1 ON Output to pin 27 x 1 OFF IORDY output is disabled Specify wether to output the IORDY signal to pin 27 of the HOST interface. When the data transfer rate of the host is very high (around 7.4MB/s), the IORDY signal is output to synchronize data transfer by inserting wait states. SW1 Connection to the spindle synchronous signal ------------------------------------------------- 2 ON Connected to HOST interface x 2 OFF Not connected to HOST interface SPSYNC line is disconnected Specify wether to connect pin 28 of the HOST interface The SPSYNC switch is provided as an option. SW1 Write-protect ------------------- 3 ON Write-protected x 3 OFF Write protect is disabled SW1 7-byte ECC in write/read LONG mode ---------------------------------------- 4 ON 7 Byte The number of ECC bytes in LONG mode is always 7 bytes regardless of the setup of the host. x 4 OFF 4 Byte The number of ECC bytes in LONG mode depends on the setup done with the SET FEATURES com- and. The default setup after power-on is 4 bytes. SW1 Slave present mode/Active mode ------------------------------------ 5 ON Slave drive x 5 OFF Master drive SW1 For factory use --------------------- 6 CNH1 SPINDLE SYNC execution ---------------------------- x 1- 2 OPEN SPINDLE SYNC is not performed 1- 2 CLOSE SPINDLE SYNC is executed The SPINDLE SYNC operation is provided as an option. CNH1 SPSYNC signal OUTPUT/INPUT mode ------------------------------------- x 3- 4 OPEN OUTPUT mode SPSYNC signal is sent to the I/F pin 28 3- 4 CLOSE INPUT mode SPSYNC signal is received from the I/F pin 28 The SPSYNC signal mode is provided as an option. CNH1 Reserved -------------- 5- 6 7- 8 ********************************************************************** I N S T A L L ********************************************************************** FUJITSU M2622T/M2623T/M2624T OEM MANUAL 41FH5066E-01 Notes on installation ===================== Installation direction ---------------------- horizontally vertically +---------------+ +--+ +--+ | | | +-----+ +-----+ | | | | | | | | | +--+---------------+---+ | | | | | | +----------------------+ | | | | | | | | | | | | X X | | | | | | +------X-------X-------+ | | | | | | +--+-----X---X-----+---+ | +-----+ +-----+ | | X X | +--+ +--+ | X X | +--X--------X---+ X X If the drive is installed in any of the above three installation directions, the level deviation must not exceed 5*. Never install PCA to the top! Ambient temperature ------------------- The operating temperature range for the IDD in a cabinet is specified at a distance of 3 cm from the IDD. Design the air flow in the cabi- net to keep. Pay attention to the air flow to prevent the DE surface temperatue from exceeding 65*C. The air circulation in the cabinet must be designed so that the PCA side of the IDD is particularly cooled. Multi-drive connection ---------------------- Up to two IDDs are connectable. Note: To use a daisy-chain configuration (2-drive system), the disk drives must be connected to an M261xT series machine or an ATA-com- patible machine in principle. Operation cannot be assured for daisy- chain configurations with other machines. +------------+ ATA interface +-----+ | Host PC +-------------+--------------+ IDD | +------------+ | +-----+ | +-----+ +--------------+ IDD | +-----+ Cable requirements ------------------ The cable of twisted pairs and neighboring line separated individu- ally is not allowed to use for the host interface cable. It is because that the location of signal lines in these cables is not fixed, and so the problem on the crosstalk among signal lines may occur. Cable length: 0.5m Max. External operator panel connector --------------------------------- CN5 So that the front panel LEDs can be mounted externally, the disk drive has an external operator panel connector. The ex- ternal LED indication is the same as the LED indication on the front panel of the disk drive. Interface Connectors -------------------- +--------------------+--------------+-----------------+-------------+ | |NAME |MODEL |MANUFACTURER | +--------------------+--------------+-----------------+-------------+ |AT interface cable |Cable socket |FCN-707B040-AU/B |Fujitsu | |(40-Pin, CN1) | |(closed end) or | | | | |FCN-707B040-AU/O | | | | |(Thru end) | | | | | | | | |Signal cable |87711-004 |DUPONT | | | |445-248-40 |SPECTRA-STRIP| +--------------------+--------------+-----------------+-------------+ |Power supply |Cable socket |1-480424-0 |AMP | |cable |housing | | | | |Contact |170148-2 |AMP | | | | | | | |Signal cable |86260-001 *1 |DUPONT | | | | | | | | |AWG 18 to 24 | | +--------------------+--------------+-----------------+-------------+ |DC ground |Quick-connect |62187-1 |AMP | | |receptable | | | | |(FASTON) | | | | | | | | | |Cable |AWG 20 | | +--------------------+--------------+-----------------+-------------+ |External operator |Cable socket |608283392815000 |ELCO | |panel (CN5) |housing | | | | |Contact |608283052330808 |ELCO | | | |(AWG 24 to 30) | | | | |608283252330808 | | | | |(AWG 32) | | +--------------------+--------------+-----------------+-------------+ ********************************************************************** F E A T U R E S ********************************************************************** FUJITSU M2622T/M2623T/M2624T OEM MANUAL 41FH5066E-01 Media Defect ============ Defect sectors are replaced with alternates when the disk is format- ted prior to shipment from the factory (low level format). Thus, the host sees a defect-free device. Alternate sectors are automatically accessed by the disk drive. The user need not be concerned with access to alternate sectors. Known defects, for which alternative blocks can be assigned, are not included in the error rate count. It is assumed that the data blocks to be accessed are evenly distributed on the disk media. Drive BIOS specification ======================== The disk drive uses constant density recording technology (all cylinders are classified into four areas and the recording density varies in each area). The number of sectors/track varies with the area. Therefore, the disk drive constantly performs logical/physical translation (emulation) and the host must access the disk drive according to the BIOS specifications (logical parameters). The number of sectors/track and the number of heads in the BIOS specifications are defined by the INITIALIZE DRIVE PARAMETERS (or SET PARAMETERS) command from the host. Table 6.1 describes the BIOS specifications that allow the physical capacity of the disk drive to be used most effeciently. The disk drive has a low-level format with these parameters as shipped from the factory. Table 6.1 |M2622T|M2623T|M2624T| -------------------+------+------+------+ Number of cylinders|1013 |1002 | 995 | Number of heads | 10 | 13 | 16 | Sectors/track | 63 | 63 | 63 | -------------------+------+------+------+ Total capacity | 326MB| 420MB| 513MB| IF able to change the fixed disk parameter table in the BIOS, the user can select parameters and incorporate them into the BIOS speci- fications. However, the selected parameters must satisfy the capaci- ties listed in Table 6.1. It is also possible, to select items (within the capacity of Table 6.1) from the existing drive type table in the BIOS of the system. The disk drive operates as a device of the capacity of the selected drive type (parameter). Low-Level Format ================ A low-level format is executed from the factory with the parameters listed in Table 6.1. The disk is formatted such that defects are invisble to the host. ********************************************************************** G E N E R A L ********************************************************************** FUJITSU => GDT Tips & Hints about ICP controllers and other peripherals ======================================================== Tagged queues and Fujitsu M 26xx harddisks ------------------------------------------ Fujitsu Harddisks of the M26XX series do not support the SCSI-II feature tagged queues. You should disable this feature in the initialize disks menue of the GDTSetup program. An inquiry command shows, that the harddisk supports tagged queues (this is why you can enable it in the GDTSetup) but this is not true as stated by Fujitsu Germany.